How to Factory Reset a Tibbo Module?

Created by Admin Sensor, Modified on Thu, 14 May at 1:01 PM by Emma Roberts

Factory Resetting a Tibbo Module



1. To initialise a Tibbo module, begin by entering the programming mode: 

    If using EXT-TCP board, press on the SW2 button once (RESET BUTTON ON TIBBO BOARD)


2. If using IC1000/500-IP board, shortcut the JP3 jumper briefly.


3. If using IC2000/4000 board, shortcut the JP4 jumper briefly.


4. The red and green LEDs should blink continuously.
     Wait for at least 5 seconds. 


5. Press/shortcut again the same button/jumper and hold it for 5 seconds, until the green

     LED lights up continuously.


6. Power off and power on the board.

    The Tibbo module is initialized its default IP address is 127.0.0.1


7. Configure the Tibbo module with DS MANAGER of Tibbo Toolkit.